By Institution Of Engineering And Technology, Electricity Training Assoc

A collection of 4 volumes compiled by way of top experts within the electrical energy provide and production businesses to supply a complete therapy of strength process protection.

Also available:

Power procedure defense 2: platforms and strategies - ISBN 9780852968369
Power approach safeguard three: software - ISBN 9780852968376

The establishment of Engineering and know-how is among the world's best specialist societies for the engineering and know-how neighborhood. The IET publishes greater than a hundred new titles each year; a wealthy mixture of books, journals and magazines with a again catalogue of greater than 350 books in 18 diversified topic parts together with:

-Power & Energy
-Renewable Energy
-Radar, Sonar & Navigation
-Electromagnetics
-Electrical Measurement
-History of Technology
-Technology Management

Show description

Read Online or Download Power System Protection Volumes 1-4 PDF

Best nonfiction_6 books

Second Book of Lankhmar (Fantasy Masterworks 24)

2 British Sized exchange Paperbacks. the 1st e-book OF LANKHMAR & the second one booklet OF LANKHMAR. 2 monstrous Fafhrd and the grey Mouser Omnibus variants containing all 7 in their books. myth Masterworks sequence. released by means of Gollancz (UK, Orion Publishing). the 1st ebook OF LANKHMAR (2001 delusion Masterworks quantity 18, 762 pages, includes: Swords and Deviltry, Swords opposed to loss of life, Swords within the Mist, Swords opposed to Wizardry).

Extra info for Power System Protection Volumes 1-4

Example text

Clearly a method of discriminating between a fault and normal or overload conditions is a necessity, and such a method is available if use is made by suitable circuitry of the fact that the currents in a three phase system can be resolved into their positive, negative and zero sequence components. (a) Zero-phase sequence systems: Faults involving earth give rise to zero-sequence currents which can be used as a basis for discrimination. The value of discriminative methods which isolate the zero-sequence component usually resides in their ability to ignore load currents and phase-tophase short circuits, thus permitting the use of earth-fault relay settings lower than load current values.

To understand this function of back-up protection it is necessary to explain that with every protective installation there is associated a 'protected zone' which is def'med, for a unit system, as the zone lying between the two or several sets of current transformers which together with the relays constitute the protective system; and, for a non-unit system, the zone lying between the current transformers and the point or points on the protected circuit beyond which the system is unable to detect the presence of a fault.

This perhaps rather fanciful approach illustrates very well the essentials of a unit protection system, which can be stated thus: (i) there must be fault-sensing means at each end of the protected circuit; (ii) there must be means of communication between the ends so that the fault-sensing means at each end is simultaneously acquainted with conditions at the other end (or ends), so that its tripping function can be exercised or not as appropriate. 28 Protection principles and components (h) Phase-comparison method: In situations where the means of communication between circuit ends is unable to provide a linear transmission of current amplitude information, a comparison between relative phase angles is often possible.

Download PDF sample

Rated 4.99 of 5 – based on 9 votes